- 1/2 Pint Grease Cup New Style, Flanged Slotted
|
1st Exhaust Fan |
|
VXB14 Belt Drive Centrifugal Upblast Exhaust Fan with 15.75" wheel
Exhaust Fan handles 2000 CFM @ -0.625" wc. Fan runs at 1074 RPM.
Exhaust Motor: 0.500 HP, 1 Phase 115 V, 8.0 FLA, ODP (Open Drip Proof) |
|
- GREASE CUP - Grease Cup for kitchen-duty centrifugal exhaust fans,
Box Dimensions 15-3/4 L X 5-1/16 W X 3-3/4 H (18 GA.) |
|
- Curb CRB23X20E On Fan # 1 |
|
- Hinged Base for Curb. Standard Hinge attached to curb. Used on Fans with wheels 24 inches or smaller. 10 GA Galvanized. |
|
- Vented Base for Curb
|
2nd Exhaust Fan |
|
VXB14 Belt Drive Centrifugal Upblast Exhaust Fan with 15.75" wheel
Exhaust Fan handles 2000 CFM @ -0.625" wc. Fan runs at 1074 RPM.
Exhaust Motor: 0.500 HP, 1 Phase 115 V, 8.0 FLA, ODP (Open Drip Proof) |
|
- GREASE CUP - Grease Cup for kitchen-duty centrifugal exhaust fans,
Box Dimensions 15-3/4 L X 5-1/16 W X 3-3/4 H (18 GA.) |
|
- Curb CRB23X20E On Fan # 2 |
|
- Hinged Base for Curb. Standard Hinge attached to curb. Used on Fans with wheels 24 inches or smaller. 10 GA Galvanized. |
|
- Vented Base for Curb
|
Supply Fan |
|
VSA12 Supply Unit with 12" Blower in Size #2 Housing
Supply Fan handles 3200 CFM @ 0.250" wc. Fan runs at 657 RPM.
Supply Motor: 1.000 HP, 1 Phase 115 V, 14.0 FLA, ODP (Open Drip Proof)
Down Discharge - Air Flow Right -> Left |
|
- Sloped Foam Filtered Intake for Size #2 Standard Untempered Make-Up Air Unit with 12" blower wheel.
22" Wide x 29.25" Long x 31.5" High.
Includes 2" Foam EZ Kleen Metal Mesh Filters. |
|
- Curb CRB32.5x14 On Fan # 3 |
By Others: Installation, ductwork, patching, all electrical field wiring, start-up & balance, gas or electric
shutdown for fire system hook-up, fire system hook-up, fire system chemical agent, NO2 cartridge, field piping, detection and pull station line(s), tests and permits.
Note: Customer is responsible for additional labor charges as a result of cooking equipment layout changes after the release of the order, union labor charges, or additional trips by fire system distributor caused by jobsite delays, permits, fees or test required by local authority. Submittal will specify applicable testing and approval agencies. The fire suppression system final hook up is not included on this quote. The final hook up usually consists of, but is not limited to, the chemical agent, NO2 cartridge, field piping/re-piping, detection and pull station line(s), tests, and permits.
Ventilation Direct product must be installed in accordance with installation instructions provided with equipment or available on our web site at www.ventilationdirect.com.
Ductwork must be designed and installed in accordance with AMCA and ASHRAE standards as presented in Ventilation Direct "Guide to Designing Air Flow Systems", available at: http://www.ventilationdirect.com/MANUALS/AIRSYSTEMDESIGN/DESIGNAIRSYSTEMS.HTM
Freight includes one shipment only, delivered to the job site address listed on this proposal. Customer is responsible for freight charges on any items shipped early. Customer si responsible for unloading equipment.
| | |