| | |
|
Bidding has ended on this item. The seller has relisted this item or one like this. Item:Air Conditioning Unit 7.5 Ton, Self-Contained, |
|
|
Unused in Original Crate with Manuals
7.5 Ton, Self-Contained, Air Conditioning Unit Corrosion Resistant Copper/Nickel Piping This unit is designed with corrosion resistance piping. Copper/nickel piping in accordance with Mil-F-16420, alloy 706, Type 1, Class 200, Grade 1 is recommended. A strainer is provided(shipped inside the compressor compartment) for installation in the supply line to the unit. The inlet connection is a union threadpiece and the oulet is a union tailpiece. The mating unions are provided (threaded loosely to the condenser head inlet and water regulating valve outlet). The connection pipe sizes are, Inlet: 1.25 inch and Outlet:1.25 inch. This unit is designed to mount on a solid surface with (4) 3/4-inch bolts & nuts, with washers. However, the unit can be mounted on structral rails. The rails must be at least 4-1/2 inches wide and positioned at the front, back and sides of the unit. Removable Plenum comes attached. The thermostat can be adjusted to maintain constant room temperature between 60 and 95F. The motor pulley is a variable speed pulley that can be adjusted to maintain the proper constant blower speed. Installation, Operating and Maintenance manuals are included. Please Note: This unit was designed to be used with sea water on a military vessel (reasoning for 70/30, copper/nickel). If land based operation is desired a water cooling tower may be required. These units are water cooled and the water discharge can either (a) be used in conjunction with a water cooling tower to recycle the water in a closed loop system or (b) the discharge city water can be sent down the drain becoming very costly at the end of the month with so many gallons of water being used. If you have questions, or need additional information, please feel free to contact me with your concerns. Model # SCAC-7.5 Physical Data Minimum Air Flow (CFM): 2250 - Height (in.) Capacity (Btu/hr)-with plenum: 75 -Normal: 90,800 -without plenum: 65 -Overload: 112,500 -Width (in.): 48 Waterflow (GPM) -Depth (in.): 25 -Normal: 28 -Weight (lbs.) with controller -Overload: 35 -Dry: 1100 Blower Speed (RPM) -Wet: 1125 -with plenum: 900 Electrical Data -without plenum: 1130 -Power Supply (3ph-60Hz-440V) Refrigerant Type: R-22 -Current (Amps) Refrigerant Charge (lbs): 20 -Normal: 13.3 -Overload: 14.5 -Power Input (Watts) -Normal: 9060 -Overload: 9762 Normal: Based on 80F dry bulb/ 67F wet bulb entering air temperature, 95F entering water temperature, and 35 psig entering water pressure. Overload: Based on 100F dry bulb/85F wet bulb entering air temperature, 100F entering water temperature, and 35 psig entering water pressure. Shipping Weight: 1365LBS. Please contact for shipping quotation. |
Shipping and handlingItem location: Macon, Georgia, United States Services available: Freight - Check the item description or contact the seller for details Ships to: United States |
Return policy
| |||||||
Payment details
Seller's payment instructions | ||||||