UPS Protection has been protecting systems against brownouts, blackouts and poor power quality for over 25 years. We provide UPS systems and services for clients from coast to coast and specialize in solving all UPS needs. As a direct reseller of the best brands in the industry, we can solve all of your power protection needs.
Output Power Capacity
2400 Watts / 3000 VA
Max Configurable Power
2400 Watts / 3000 VA
Nominal Output Voltage
120V
Output Voltage Distortion
Less than 5% at full load
Output Frequency (sync to mains)
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
Output Connections
| (6) NEMA 5-15R |
|
| (2) NEMA 5-20R |
|
Nominal Input Voltage
120V
Input Frequency
50/60 Hz +/- 3 Hz (auto sensing)
Cord Length
8 feet (2.44 meters)
Input voltage range for main operations
92 - 147V
Input voltage adjustable range for mains operation
86 - 154V
Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time
3 hour(s)
Typical Backup Time at Half Load
18.7 minutes (1200 Watts)
Typical Backup Time at Full Load
5.7 minutes (2400 Watts)
Runtime Chart
Communications & Management
Interface Port(s)
DB-9 RS-232,SmartSlot
Available SmartSlot™ Interface Quantity
1
Control panel
LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : and Overload Indicators
Audible Alarm
Alarm when on battery : distinctive low battery alarm : configurable delays
Emergency Power Off (EPO)
Optional
Surge Protection and Filtering
Surge energy rating
880 Joules
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Maximum Height
5.25 inches (133 mm)
Maximum Width
19.00 inches (483 mm)
Maximum Depth
26.00 inches (660 mm)
Net Weight
124.00 lbs. (56.36 kg)
Shipping Weight
139.00 lbs. (63.18 kg)
Shipping Height
12.00 inches (305 mm)
Shipping Width
24.00 inches (610 mm)
Shipping Depth
32.00 inches (813 mm)
Operating Environment
32 - 104 °F (0 - 40 °C)
Operating Relative Humidity
0 - 95%
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
5 - 113 °F (-15 - 45 °C)
Storage Relative Humidity
0 - 95%
Storage Elevation
0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit
53.00 dBA
Online Thermal Dissipation
375.00 BTU/hr
For any questions contact us at: (800) 755 - 0080 or sales@upsprotection.com
UPS Protection – Condition Rating
Rating |
Description |
|
1 |
Unused - still in the original box, new condition without manufacturer warranty. |
|
2 |
Refurbished – some minor cosmetic imperfections, looks close to new, gently used. |
|
3 |
Refurbished – shows signs of use, some scratches, blemishes, shows signs of use. |
|
4 |
Refurbished – may contain dents, non-critical cracks, fully functional, signs of heavier use. |
|
5 |
Parts Unit – sold with some components missing, damaged or non-functional unit. |
No accessories are included, unless noted.
Local pickups are welcome. For maps click here.
We accept American Express, Discover, Mastercard, Paypal and Visa.
California residents pay sales tax.
WARRANTY UPS Protection stands behind all of our products with a one to two year warranty. The warranty is as follows:
Warranty Policy UPS PROTECTION, INC. offers a One to Two Year limited replacement only warranty on all refurbished products sold from date of Invoice. UPS PROTECTION, INC. offers a 1 year limited replacement only warranty on all brand new battery kit products sold from date of Invoice. All products to be found defective by a UPS Protection technician within warranty period will be replaced by UPS Protection, Inc.. Customers must obtain a Return Merchandise Authorization (RMA) number before shipping your product back to UPS PROTECTION, Inc. Products being returned for replacement will not be accepted without a valid RMA number.
This limited warranty does not cover product against cosmetic imperfections or damage due to (1) acts of God, accident, misuse, abuse, negligence or modifications of this product; (2) improper operation or maintenance of this product; (3) connection to improper voltage supply; or (4) attempted repair by any party.
All NON-DEFECTIVE returns or incorrectly ordered products requesting credit are subject to RMA approval at the sole discretion of UPS Protection and subject to a 20% percent restocking fee of total invoiced amount.
For faster service, please have the following information on hand when calling UPS Protection, Inc. customer services: customer name, invoice number, serial number(s). Shipping charges on items to be returned are the customer's responsibility; UPS PROTECTION, INC. will pay for shipping on replacement item(s) in the first 30 days after invoice. From 30 days until the end of the warranty period, customer pays freight costs to UPS Protection and UPS Protection pays freight costs back to customer.
If you receive damaged merchandise, it is best to REFUSE it back to the carrier attempting delivery. If you accept the package make sure it is noted on the carrier's delivery record in order for UPS PROTECTION, INC. to file a damage claim. Save the merchandise AND the original box and packing it arrived in, notify UPS PROTECTION, INC. immediately to arrange for a carrier inspection and a pick up of damaged merchandise. If you do not notify UPS PROTECTION, INC. of damaged goods within the first 15 days of arrival, our regular warranty policy will override any claim of damage. Contact Customer Service at 800.755.0080 to arrange for carrier inspection and a pick up of damaged merchandise.
Items determined to be DEFECTIVE must be returned directly to UPS PROTECTION, INC. within 30 days from RMA issuance date, for replacement or credit at the discretion of UPS Protection. In instances where UPS Protection cannot supply the equivalent replacement product purchased because of product availability, we will offer comparable alternative or credit refund upon receipt RMA product.
|