16 kW Air-Cooled Standby Generator
Big Generator Protection… Half the Price More power, more features and an exceptional price make the GUARDIAN QuietSource™ 16 kW the best value in automatic standby generators. With GUARDIAN’s new breakthrough technology, the 16 kW provides the circuit protection of a much larger generator at a truly remarkable price. If you need to run more than one air conditioner, the GUARDIAN QuietSource 16 kW is the affordable solution. With 33% more circuit coverage than our 13 kW, this powerhouse can start a 5-ton AND a 3-ton, or two 4-ton air conditioners with plenty of power to spare.
Whisper Quiet Operation GUARDIAN’s exclusive patent-pending Whisper-Test™ low speed exercise feature makes the GUARDIAN QuietSource 16 kW the quietest air-cooled generator on the market. Whisper-Test reduces noise to less than 59 dBA during the weekly automatic self-test. That’s quieter than your central air conditioner.
With our pre-packaged, 16-circuit pre-wired system, installation is fast, easy and inexpensive, making the 16 kW an even better value.
- Breakthrough Design: Newly designed alternator can start a 5-ton AND a 3-ton, or two 4-ton air conditioners with plenty of power to spare
- Circuit Coverage: Protects 16 circuits of your home
- Automatic Voltage Regulator: Quality electrical output for sensitive electronics
- Electronic Governor: Fast response to changing electrical loads
- Whisper-Test™: Patent-pending, self-test feature makes the GUARDIAN QuietSource quieter than your central air conditioner
- Generac OHVI® Industrial Engine: The ONLY air-cooled engine designed specifically for generators
- Longest Life Expectancy in the Industry: Over 3,000 hours of run time
- Full Pressure Lubrication: Continuous lubrication of all vital engine parts for protection from moment of start up for ultimate engine protection
- Spin-on Oil Filter: Automotive style for easy maintenance and prolonged engine life
- Superior Paint: Tough, textured powder coat paint finish for unmatched durability and all weather protection
- UL Listed: For safety and certified power ratings
- Clean Burning Fuel: Natural gas or LPV
|
Automatic Distributed Load Center
The Generac Guardian Models come standard with a pre-packaged transfer switch load center to select individual circuits which will be used during emergency operation. Installation is easy and inexpensive. The Model 5243 includes a 16 circuit panel, a 30 foot, and a 2 foot pre-wired conduit, a pre-wired external connection box and UL Listed wire nuts as standard equipment.
| Rated Power LP (kW) |
16 |
| Rated Power NG (kW) |
15 |
| Voltage @ 60 Hz |
120/240 |
| Phase |
Single |
| Frequency |
60 Hz |
| Amps LP |
133.3/66.6 |
| Amps NG |
125.0/52.5 |
| Engine/Altenator RPM |
3600/3600 |
| Engine |
992cc 30 HP Generac OHVI V-Twin |
| Fuel Comsumption LP (cu.ft./hr.)/(gal./hr.) |
92 (2.51) |
| Fuel Consumption NG (cu.ft./hr.) |
245 |
| EPA/CARB Certified |
Yes |
| Fuel |
Natural Gas/LP Vapor |
| Engine Cooling |
Air |
| Enclosure |
Steel |
| UL 2200 (US and Canada) |
Yes |
| Sound Output dB(A) at 23 ft. with generator operating at full load |
71.5 |
| Sound Output dB(A) at 23 ft. with generator in WhisperTest™ low speed exercise mode |
61 |
| Main Line Circuit Breaker |
65 Amp |
| Dimensions (L" x W" x H") |
48 x 24 x 28-1/4 |
| Unit Wt. (lbs.) |
445 |
| Controls |
|
Engine Start Sequence |
Cyclic cranking: 7 sec. on, 7 sec. rest. 90 sec. maximum duration |
| Automatic Low Oil Shutdown |
Standard |
|
Overspeed Shutdown |
Standard, 72 Hz |
|
Overcrank Protection |
Standard |
| Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
| Engine Warmup |
10 seconds |
| Engine Cool-Down |
1 minute |
| Safety Fuse |
Standard |
| Starter Lockout |
Starter cannot re-engage until 5 seconds after the engine has stopped |
| 2.5 Amp Timed Trickle Battery Charger |
Standard |
| WhisperTest™ |
Sound Output is 61 dB(A) at 23 ft. with generator in WhisperTest™ exercise mode |
| Auto Switch |
Automatic start on utility failure/7 day exercise |
| Off Switch |
Stops unit. Power is removed. Control and charger still operate |
| Manual / Test (start) |
Start with starter control, unit stays on. If utility fails, transfer to load takes place |
| Full Monitoring System |
Oil pressure, coolant temperature, engine speed, coolant level, cranking time, starter lockout, utility sensing |
| Shutdown and LED Indicators |
Overspeed and overcrank, low oil pressure, high coolant temperature, low coolant level, low fuel pressure, low battery voltage |
| Transfer Switch |
|
No. of Poles |
2 |
| Current Rating (amps) |
100 |
| Voltage Rating (VAC) |
250 |
| Utility Voltage Monitor (fixed) |
| - Pick-up |
70% |
| - Drop out |
60% |
| Return to Utility |
Approx. 13 seconds |
| Exercised 7 minutes weekly |
Standard |
| UL Listed |
Yes |
| Dimensions (H" x W" x D") |
26.5 x 12.5 x 7 |
Installation Video
GUARDIAN® air-cooled generators are pre-wired and pre-packaged, making installation easy for you, your electrical contractor or one of our authorized dealers.
A DVD of this installation video along with an Installation Guidelines booklet will be packaged with every generator purchased.
|
| Air-Cooled and Liquid-Cooled Units |
Standard |
2 Year |
Warranty |
Selecting a System
Protection Made Easy… When choosing your GUARDIAN® Standby Generator, you must first decide how many circuits or rooms you want to protect. Nobody makes it easier than GUARDIAN!
With our pre-packaged, air-cooled systems, all you have to do is match the circuits in our automatic transfer switch to those in your home’s main distribution panel. Then, simply total the number of circuits and correlate that to the generator that best matches your needs. There is absolutely no reason to calculate wattages, since you’ll never use all of your appliances at once. That’s why GUARDIAN leads the industry in creating powerful, yet economical and easy to install emergency standby generators.
For additional wattage requirements, please see our GUARDIAN QuietSource™ liquid-cooled models. |
How it Works
 View "How it Works" Video
GUARDIAN® Standby Generators are completely automatic, helping to ensure that you remain safe from the negative and potentially harmful effects of power loss.
1. The GUARDIAN system automatically and continuously monitors incoming power from the utility line. 2. When utility power is interrupted, the control system in the generator automatically senses the loss of power and signals the generator to start. 3. The automatic transfer switch safely closes off the utility line and simultaneously opens a new power line from the generator. 4. Your GUARDIAN generator supplies electricity to the critical circuits you previously chose to back up. 5. When utility line voltage returns, the system transfers the electrical load back to the utility line. The generator continues to run for an engine cool-down period of several minutes and the entire system stands ready for the next power outage.
To ensure the system is always ready when you need it, your generator will run a 10-12 minute self-test cycle every week. __________________________________________________
Selecting a System
 View "How Select a System" Video
Protection Made Easy… When choosing your GUARDIAN® Standby Generator, you must first decide how many circuits or rooms you want to protect. Nobody makes it easier than GUARDIAN!
With our pre-packaged, air-cooled systems, all you have to do is match the circuits in our automatic transfer switch to those in your home’s main distribution panel. Then, simply total the number of circuits and correlate that to the generator that best matches your needs. There is absolutely no reason to calculate wattages, since you’ll never use all of your appliances at once. That’s why GUARDIAN leads the industry in creating powerful, yet economical and easy to install emergency standby generators.
For additional wattage requirements, please see our GUARDIAN QuietSource™ liquid-cooled models. __________________________________________________
Installation
 View "Installation" Video
GUARDIAN® air-cooled generators are pre-wired and pre-packaged, making installation easy for you, your electrical contractor or one of our authorized dealers. To view our installation video (242 MB), please click on the image to the right.
A DVD of this installation video along with an Installation Guidelines booklet will be packaged with every generator purchased.
Note: Neither the installation video nor the Installation Guidelines booklet replace or supersede any information contained the Owner’s Manual, Installation Guide, technical manuals or any other documents packaged with your equipment. __________________________________________________ |