Watch this item
Please wait
Image not available
Mouse here to zoom in
Please wait
Image not available

LEAK STOP SUPER SEAL COMMERCIAL INDUSTRIAL STRENGTH

Item condition:New
Quantity:
2 available
Please enter a quantity of $quantity$ or less
Please enter a quantity of 1
Price:US $63.99Buy It NowBuy It NowBuy It Now
Shipping:$4.95US Postal Service Priority Mail Medium Flat Rate BoxSee more services 

Country:
ZIP Code:
Quantity:
(available quantity 2)
Service and other details:
Service
Estimated delivery*
Price
US Postal Service Priority Mail Medium Flat Rate Box
3-4 business days
$4.95
*The estimated delivery time is based on the seller's handling time, the shipping service selected, and the payment method selected. Sellers are not responsible for shipping service transit times. Transit times may vary, particularly during peak periods.

 See discounts 

 |  See all details
Estimated delivery within 3-4 business days
Returns:
No Returns Accepted
Coverage:
Pay with and your full purchase price is covered | See terms

A reserve price is the minimum price the seller will accept. This price is hidden from bidders. To win, a bidder must have the highest bid and have met or exceeded the reserve price.

 
99.9% Positive feedback
Get fast shipping and excellent service from eBay Top-rated sellers.
  • Consistently receives highest buyers' ratings
  • Ships items quickly
  • Has earned a track record of excellent service
Other item info
Item number:400081181265
Item location:Hartford, Wisconsin, United States
Ships to:Worldwide
Payments:
Item specifics
Condition: New  
Visit my eBay store

CLASSIC SUPER SEAL COMMERCIAL™

 SUPER SEAL

CLIPLIGHT COMPANY, simplifing A/C and Refrigeration repair

"THE NEW APPROACH FOR HARD TO FIND MICRO LEAKS"

COMMERCIAL INDUSTRIAL

STRENGTH FORMULA

Part# 948KIT

REPAIRS HARD TO FIND LEAKS AND CONTINUES TO CIRCULATE IN THE SYSTEM TO SEAL FUTURE LEAKS.

Industrial Formula - For Commercial/Industrial Systems
5 ton/17.6KW systems or larger

  • For professional use only: Always wear safety glasses and protective gloves
  • Do not use on mobile systems, ask for Classic Super Seal Premium™ or Classic Super Seal Pro™
  • Use in compliance with the Montreal Protocol and Regional or Federal laws for the handling of refrigerant.

 

»Watch Video



Industrial Formula - For Commercial/Industrial Systems
5 ton/17.6KW Air Conditioning or Refrigeration systems or larger

  • For professional use only: Always wear safety glasses and protective gloves
  • Permanently seals micro leaks in condensers, evaporators, and lines in A/C and Refrigeration systems.
  • Do not use on mobile systems, see our Classic Super Seal Premium™ or Classic Super Seal Pro™
  • Easily Installed in Minutes
  • Seals hard to find micro leaks
  • Compatible with ALL oils and refrigerants
  • For use in systems with a minimum of 4 lbs/1.82 Kg. of refrigerant.
  • Perfect for most industrial applications
  • Ideal for leaks caused my formicary (ants nest) & internal acid corrosion, vibration, and temperature variation.
  • Complete one time use throw away kit
  • Includes charging hose
  • Use in compliance with the Montreal Protocol and Regional or Federal laws for the handling of refrigerant.


    SUPER SEAL COMMERCIALTM


    Super Seal is a light or low viscosity particle free
    liquid, that travels with the oil and refrigerant
    throughout the system.

    When a leak is detected Super Seal forms a low
    tensile crystalline structure, at point of leakage,
    when activated by moisture from the
    surrounding air.


    Industrial Formula - For Commercial/Industrial
    Systems 5 ton/17.6KW or larger
     
    For professional use only:

    Always wear safety glasses and protective gloves

     
    Do not use on mobile systems ask for Super Seal PremiumTM/ Super Seal Pro

    Use in compliance with the Montreal Protocol and Regional or Federal laws
    for the handling of refrigerant.


    Important before proceeding:


    You should not be losing more than 14% of the entire refrigerant charge over a 4 week period to have maximum results with Super Seal.

    Sealant should only be injected into a refrigeration system that is moisture and contaminate free, as this could cause premature compressor failure.

    It is highly recommended to use Cliplight DRY R to remove moisture prior to
    installation of Sealant and proceed as follows;

     

    Before installing Super Seal COMMERCIALTM check the overall condition of the unit.

    The system should be operating within its approximate normal pressure/ temperature conditions.

    Check the compressor by taking a temperature reading at its base.


    Readings above 130°F/ 54°C or compressor discharge temperatures above 225 F (107.2 C) may indicate a line restriction or low oil/refrigerant charge.

    Measure temperature at inlet and outlet of liquid line drier; a temperature differential of 2 degree or greater indicates drier replacement is necessary.

    Failure to replace a contaminated or plugged filter drier may result in compressor failure.

    Where there is the possibility of refrigerant contamination an acid/moisture test should be performed and followed up with recommended clean up procedure.

    If the system has to be evacuated it is advisable to change both liquid and suction line driers and obtain a minimum of 350 microns or less to eliminate moisture and non-condensable.

    Charge to factory required levels.

    INSTRUCTIONS A:

    clock wise = cw and counter clockwise = ccw

    Install into a fully charged system.

    Instructions A can be used when static pressure of 410A system is 300 psig or lower.

    The term static pressure refers to the equalized system pressure when the unit is off.

     

    1. Turn off A/C or R unit and allow enough time for refrigerant to equalize in system.

    2. Confirm that can tapper piercing pin (B) is fully retracted below seating washer. Turn valve handle (A) ccw

    3. Thread Super Seal COMMERCIALTM can (C) onto can-tapper (B) by turning cw. Be careful not to cross thread or over

    tighten.

    4. Thread female fitting (D) onto vacuum pump and draw vacuum for approximately 1 minute to eliminate air in tap hose.

    (Where Regional and Federal laws permit you may use systems refrigerant to purge hose.)

    5. Remove female fitting (D) from vacuum pump while it is running to maintain vacuum in tap hose. After disconnecting shut down vacuum pump.

    6. Thread female fitting (D) onto low side service port immediately after removing from vacuum pump.

    7. Turn can-tapper piercing handle (A) cw until it stops.

    This action pierces the can.

    8. Hold can upside down and above the low side service port.

    Turn handle (A) ccw slowly allowing the system's refrigerant to fully charge can.

    The can will become warm once the refrigerant mixes with its contents.

    Allow the can to dissipate the

    additional heat of charging which should take between 5 to 10 minutes depending on systems charge and ambient air

    conditions.

    When the can's temperature has equalized with ambient air conditions then proceed with next step.

    Be sure to check that all connections from can to unit are secure and that there is no leakage occurring.

    9. Turn handle (A) cw until it stops, isolating charged can from A/C or R unit.

    10. While holding the can upside down, turn on A/C or R unit.

    Slowly turn handle (A) ccw gradually releasing sealant into the system.

    This should take approximately 3 to 5 minutes.

    Releasing sealant too quickly could result in liquid slugging.

    Shake can gently to determine when empty.

    If all of the contents in can are not emptied after 5 minutes then turn can tapper piercing

    handle cw (A) until it stops.

    Turn off A/C or R unit and repeat steps 8,9 and 10 as many times as necessary to empty

    contents of can.

    This should dislodge any particles that may have entered the can from the refrigerant system.

    If this fails remove hose from low side service port, while A/C or R unit is on, and attach hose to refrigerant canister and charge can.

    Close valve CW and reattach can to low side of the A/C or R system.

    Proceed to step 6.

    11. Once can is empty remove female fitting (D) from low side service port, then shut down A/C or R unit.

    Allow system's pressure to equalize.

    The A/C or R unit should be left off for approx. 5 minutes.

    This procedure allows product to mix with systems oil and when the unit is restarted will allow for equal distribution throughout system.

    12. Reclaim residual refrigerant from can and hose using a recovery machine.

    Always purge recovery machine with dry nitrogen after reclaiming refrigerant from can and hose.

    When finished reclaiming refrigerant, dispose of can and hose.

    13. Allow Super Seal COMMERCIALTM to run 10-14 days before injecting a second can.

    IMPORTANT BEFORE PROCEEDING TO USE SUPER SEAL

    COMMERCIALTM WITH R410A SYSTEMS:

    Instructions A can be used when static pressure of 410A system is 300 psig or lower.

    The term static pressure refers to the equalized system pressure when the unit is off.

     

    The maximum allowable working pressure of the Super Seal can is 400 psig.

    Because of the higher-pressure characteristics of R 410a it is possible to exceed the can rating which could possibly lead to an accidental release of the product.

    The can has been fitted with a special safety relief valve, which will vent between 420 and 480 psig to prevent this from occurring.

    This is seen as an indent-curved arch on the bottom center of the can.

    If refrigerant needs to be recovered it is highly recommend changing out the suction and liquid line driers.

    An evacuation of 350 microns or less should then be carried out.

    After this has been accomplished, proceed with the following steps.

    INSTRUCTIONS B: clock wise = cw and counter clockwise =ccw

     

    1. Confirm that can tapper piercing pin (B) is fully retracted below seating washer. Turn valve handle ccw

    2. Thread Super Seal can (C) onto can-tapper by turning cw. Be careful not to cross thread or over tighten.

    3. Thread female fitting (D) onto vacuum pump and draw vacuum for approximately 1 minute to eliminate air in tap hose.

    4. Remove female fitting (D) from vacuum while it is running to maintain vacuum in tap hose.

    5. Thread female fitting (D) onto low side service port immediately after removing from vacuum pump.

    6. With can and hose assembly attached to low side service port perform a second evacuation from the high side

    service port. Run the vacuum pump until you obtain 350 microns or less. Close your isolation valve on your vacuum pump and watch for any increases. If the pressure increases to 600 microns in less then one minute proceed to draw vacuum again down to 350 microns or less then continue on to next step. (Do not wait for increase of pressure) Isolate gauges and vacuum pump from system using shut off valves. Do not disconnect.

    7. Hold can upside down and above the low side port. Turn can- tapper piercing handle (A) cw until it stops. This action pierces the can.

    8. Then turn handle ccw allowing product to flow from can to the unit.

    9. Once can is emptied remove can and hose assembly from low-side charging port.

    10. Proceed to carry out a third evacuation on the high side to remove any non-condensable, which may have entered the system during the installation of the sealant. This should only take between 3 to 5 minutes.

    11. Recharge unit to manufactures specifications. Remove gauges after manufactures or original existing charge has been completed.

    12. Turn unit on and perform system check to confirm that the unit is operating in peak performance using condenser and evaporator delta temperatures as a guideline. Allow the system to run for approximately 5 minutes and then shut down.

    A dwell period of another 5 minutes should allow for pressure equalization and excess sealant to migrate back to compressor oil sump. This operation is to allow for equal distribution of the sealant throughout the refrigeration system once it has been restarted.

    13. The unit can now be started and follow its normal cycle of operation.

    TAPPING VALVE AND HOSE NOT TO BE REUSED

    NOTE

    Use only on systems that contain at least 4 lbs./1.82kgs. of refrigerant.

    Super Seal 3 PhaseTM is to be used only on the low-pressure side of A/C or R unit.

    Can and hose must not be subject to pressures that exceed 300psi/20.7bar working pressure.

    Eye Contact

    Obtain medical attention.

    Skin Contact

    prolonged, obtain medical attention.

    Patent No. 6481221B2

    Super Seal training manual is available in a PDF file at www.cliplight.com/hvacr/

    : Remove contaminated clothing. Wash with soap and water. If irritation persists or if contact has been: Remove contact lenses and immediately flush eyes with water and continue washing for several minutes.: One 3oz/85ml can of Super Seal COMMERCIALTM should only be used on systems 5 ton/17.6KW or larger

    Injection Hose
    20122


    Replacement Parts


    Injection Hose
    20122



00035
Shipping and handling
Item location: Hartford, Wisconsin, United States
Shipping to: Worldwide
Quantity:
Change country:
ZIP Code:
 
Shipping and handling
Each additional item
To
Service
Estimated delivery*
US $4.95
US $2.00
United States
US Postal Service Priority Mail Medium Flat Rate Box®
3-4 business days
*The estimated delivery time is based on the seller's handling time, the shipping service selected, and when the seller receives cleared payment. Sellers are not responsible for shipping service transit times. Transit times may vary, particularly during peak periods.
Domestic handling time
Sales tax
Will usually ship within 1 business day of receiving cleared payment.
Seller charges sales tax for items shipped to: WI (5.5%).
Return policy
The seller will not accept returns for this item.
Payment details
Payment methodPreferred/AcceptedBuyer protection on eBay
Credit or debit card through PayPal
PayPal Preferred
Pay with and your full purchase price is covered | See terms
Seller assumes all responsibility for this listing.

About eBay | Announcements | Security Center | Resolution Center | eBay Toolbar | Policies | Government Relations | Site Map | Help
Copyright © 1995-2009 eBay Inc. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Use of this Web site constitutes acceptance of the eBay User Agreement and Privacy Policy.
eBay official time