Fluke 87-V Industrial True-rms Multimeter with Temperature
Fluke 87V Industrial True-rms Multimeter with Temperature, 87 V ...World Leader in Multimeters.
- Large 4-1/4 digit display with backlight
- 0.05% dc accuracy for precise measurements
- Capture transients as short as 250uS
- Filter for motor drive measurements
- Built-in thermometer
FLUKE 87-V True-rms Multimeter comes with improved measurement functions, trouble-shooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution and electro-mechanical equipment.
What's included --
- 1 Fluke 87-V Industrial True-rms Multimeter with Thermometer
- Safety designed test leads
- Users manual
- Instruction CD
FEATURES:
- True-rms ac voltage and current for accurate measurements on non linear signals
- Selectable filter for accurate voltage and frequency measurements on motor drives
- 0.05 % dc accuracy
- 6000 counts, 3-3/4 digits
- 4-1/2 digit mode for precise measurements (20,000 counts)
- Measure up to 1000 V ac and dc
- Measure up to 10 A, 20 A for up to 30 seconds
- Built in thermometer lets you carry one less tool (TC probe included)
- Frequency to 200 kHz and % duty cycle
- Resistance, continuity and diode test
- 10,000 µF capacitance range for components and motor caps
- Min/Max-Average recording with Min/Max Alert to capture variations automatically
- Peak capture to record transients as fast as 250 µs
- Relative mode to remove test lead interference from low ohms measurements
- Auto and manual ranging for maximum flexibility
- Touch Hold to capture stable readings avoiding noisy signals
- Large display digits and two-level bright white backlight for increased visibility
- Analog bargraph for fast changing or unstable signals
- Input Alert provides audible warning against wrong use of input jacks
- Improved selectable sleep mode for long battery life
- Access door for fast battery changes without breaking the calibration seal
- "Classic" design with new removable holster with built in test lead and probe storage
Electrical Safety All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the new Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.
- Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
- Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
- Measure AC current with an optional current clamp accessory
- Compare reading from the 87V with the display on the ASD
- Special shielding blocks high frequency, high-energy noise generated by large drive systems
SPECIFICATIONS:
|
Specifications |
| Voltage DC |
| Maximum Voltage: |
1000V |
| Accuracy: |
Fluke 83 V: ±(0.1%+1) |
|
Fluke 87 V: ±(0.05%+1) |
| Maximum Resolution: |
Fluke 83 V: 100 µV |
|
Fluke 87 V: 10 µV | |
| Voltage AC |
| Maximum Voltage: |
1000V |
| Accuracy: |
Fluke 83 V: ±(0.5%+2) |
|
Fluke 87 V: ±(0.7%+2) True RMS |
| AC Bandwidth |
Fluke 83 V: 5kHz |
|
Fluke 87 V: 20kHz* |
|
*with low pass filter; 3db @ 1kHz |
| Maximum Resolution: |
0.1 mV | |
| Current DC |
| Maximum Amps: |
10A (20 A for 30 seconds maximum) |
| Amps Accuracy: |
Fluke 83 V: ±(0.4%+2) |
|
Fluke 87 V: ±(0.2%+2) |
| Maximum Resolution: |
Fluke 83 V: 0.01 mA |
|
Fluke 87 V: 0.01 µA | |
| Current AC |
| Maximum Amps: |
10A (20 A for 30 seconds maximum) |
| Amps Accuracy: |
Fluke 83 V: ±(1.2%+2) |
|
Fluke 87 V: ±(1.0%+2) True RMS |
| Maximum Resolution: |
0.1 µA | |
| Resistance |
| Maximum Resistance: |
50 M? |
| Accuracy: |
Fluke 83 V: ±(0.4%+1) |
|
Fluke 87 V: ±(0.2%+1) |
| Maximum Resolution: |
0.1? | |
| Capacitance |
| Maximum Capacitance |
9,999 µF |
| Accuracy |
±(1%+2) |
| Maximum Resolution |
0.01 nF | |
| Frequency |
| Maximum Frequency |
200 kHz |
| Accuracy |
±(0.005%+1) |
| Maximum Resolution |
0.01 Hz | |
| Duty Cycle |
| Maximum Duty Cycle |
99.9% |
| Accuracy |
±(0.2% per khz +0.1%) |
| Maximum Resolution |
0.1% | |
| Temperature Measurement |
| Fluke 83 V, 87 V/E: |
-200.0°C - 1090°C |
|
-328.0°F - 1994.0°F |
|
excluding probe | |
| 80 BK Temperature Probe |
|
-40.0°C - 260°C |
|
-40.0°F - 500°F, 2.2°C or 2% whichever is greater | |
| Conductance |
| Maximum Conductance |
60.00 nS |
| Accuracy |
±(1.0%+10) |
| Maximum Resolution |
0.01 nS | |
| Diode |
|
Range 3 V |
| Resolution: |
1 mV |
| Accuracy: |
± (2 % + 1) | |
| Duty Cycle Range |
| Accuracy: |
Within ± (0.2% per kHz + 0.1 %) | |
|
Environmental Specifications |
| Operating temperature |
|
| Storage temperature |
|
| Humidity (Without Condensation) |
|
0% - 90% (0°C - 35°C) |
|
0% - 70% (35°C - 55°C) | |
| Operating Altitude |
|
|
Safety Specifications |
| Overvoltage category |
|
EN 61010-1 to 1000 V CAT III, 600V CAT IV | |
| Agency Approvals |
|
|
Mechanical & General Specifications |
| Size |
|
201 x 98 x 52 mm (with holster) | |
| Weight |
|
| Weigh With Holster and Flex-Stand |
|
| Display |
| Digital: |
6000 counts updates 4/sec. |
|
(Model 87 also has 19,999 counts in high-resolution mode.) |
| Analog: |
32 segments, updates 40/sec. |
| Frequency: |
19,999 counts, updates 3/sec at > 10 Hz. | |
| Battery life |
| Alkaline: |
~400 hours typical, without backlight | |
| Shock |
|
1 Meter drop per IEC 61010-1:2001 | |
| Vibration |
|