INSTUCTIONS:
SATELLITE FINDER MODEL SF-95, SF-95c, & SF-95c+ OPERATION:
1. Unplug the receiver from the wall.
2. Remove the coax from your LNBF.
3. Connect the coax to the SF-95b meter to the connection that says "TO REC".
4. Using a jumper coax connect to the side of the meter that says "TO LNB".
5. Connect the other end of the jumper coax to the LNBF.
6. Plug in and power up your receiver.
7. Adjust the signal level knob on the front of the meter so the reading is below 5 on the scale.
8. Do a rough adjustment for the azimuth and elevation of the dish to get a starting point. If you don't know
the azimuth and elevation settings you can use SatCalc to find your values. SatCalc is free to use and
can be downloaded at http://www.visionplus.us/satcalc.html
Full View
Like to have it on your desktop?
9. With your signal level at or below 5 on the meter, start to adjust the dish very slowly while watching the
meter. If the meter level goes above 5, adjust the knob on the front of the meter to make the meter read
at or below 5. Repeat as needed.
10.Once you have found the satellite and have peaked it to the highest possible level, go to the receiver
and confirm that you are on the right satellite.
11.If you are using a linear LNBF: After confirming the satellite is correct, adjust your LNBF by turning it in
the holder first to the right and then to the left watching the meter and stopping at the highest point in
signal.
12.Power down the receiver by unplugging the power cord.
13.Remove the meter and re-connect the coax from the receiver to the LNBF.
14.You are now ready to power up your receiver.
IMPORTANT NOTES:
• SF-95b: If you are using the SF-95b you will notice a small compass built into the side of the meter for
finding your azimuth.
• SF-95b: If you are using the SF-95b in addition to the compass, you will notice indicator lights for
verifiying that your receiver is set to Horizontal or Vertical polarity and if 22KHz tone is on or off.
• Green H/V light indicates Vertical Polarity.
• Red H/V light indicates Horizontal Polarity.
• Red 22KHz light indicates 22KHz is ON.
• When aligning a C-band dish do not use your meter in front of the dish to avoid full scale readings.
• When connecting to a LNBF with gain higher than 65dB, insert a 5dB attenuator between the meter and
the LNBF. If a attenuator is not available you may use a long coax (60 feet or more) between the meter
and the LNBF.
• If the meter needle is jumping the sensitivity is too high. Adjust the S.A. level on the back of the meter
by punching through the label where marked. Be very careful not to damage the adjustment by turning it
too far or too hard.
SPECIFICATIONS:
• Frequency Range: 950 ~ 2300 MHz
• Input Level: -25dBm ~ -75dBm
• Gain: 11 ~ 15dB
• Sensitivity(S.A.): 7 Microvolt
• Power Supply: +13/+18V DC
• Operating Range: -52 ~ -65dB (LNBF Gain) |