Watch this item

TIME DOMAIN REFLECTOMETER TDR w/F and BNC 6020-5053

Item condition:New
Price:US $1,563.00Buy It NowBuy It NowBuy It Now

or
Best Offer:Make OfferMake OfferMake Offer
Shipping:Read item description or contact seller for details. See more services 

 See discounts 

 |  See all details
Estimated delivery time varies. Seller ships within 1 day
Returns:
7 day money back, buyer pays return shipping | Read details
Coverage:
Pay with and your full purchase price is covered | See terms

A reserve price is the minimum price the seller will accept. This price is hidden from bidders. To win, a bidder must have the highest bid and have met or exceeded the reserve price.

 
Seller info
100% Positive feedback
Other item info
Item number:190245410209
Item location:San Diego, California, United States
Ships to:Worldwide
Payments:
Last updated on 02:40:10 PM PDT, Apr 01, 2009 View all revisions

SquareTrade Seal Member
SquareTrade Seal Member
SquareTrade © AP6.0

AEA technology's Time Domain Reflectometer (TDR) with BNC and RJ45 connectors for the Voice Data Video & RF Industry.

If you have any questions you can call us Toll Free in the USA at 1-866-744-3014 or at 619-575-1577!!!

20/20 TDR Highlights

The 20/20 TDR product line is a family of “Step” Time Domain Reflectometers designed for the Communications, Telephone, Broadband, and Private Network markets or wherever high bandwidth copper media testing is required.
 
The 20/20 TDR models identify and pin-point faults in all twisted pair and coax cables. The advantages of the 20/20 TDR’s step technology are the elimination of dead zones; increased informational data at the cursor location such as distance and impedance, plus higher resolution and greater accuracy over traditional pulse TDR’s. The 20/20 TDR features include multiple display formats, an intermittent fault capture, and a pair-balance test (Multi-Channel only). You can store up to 99 screen traces or 15 full range traces in the TDR memory for retrieval or downloading to the new TDR PC Vision TM software.

All Time-Domain-Reflectometer (TDR) devices are built on the same general principle. Radio Frequency waves travel at a speed that can be measured. The speed of the RF signal varies depending on the material it is traveling through. RF travels fastest through vacuum (100%) and slowest through twisted wire pair (50% to 75%).

When RF encounters an obstacle or impedance shift in twisted wire pair or Coaxial cable, some or all of the energy bounces back towards the origin end. The time it takes for this bounced energy or reflection to arrive back at the source is measured and divided by two to account for the round trip.
 
If the Velocity Factor or Velocity of Propagation (VoP) of the medium is known, the time can be translated into an accurate distance measurement. The following equation expresses the TDR’s basic principle of operation:
 
Time/2 X Velocity = Distance
 
Step verses Pulse Technology
 
Pulse technology is similar to AM Radar, where a short burst of a sine wave is transmitted. The transmitter emits a single pulse then shuts off. The TDR then enables the receiver to listen for reflections.
 
The longer the transmitted pulse, the longer the distance before the receiver can start looking for reflections. This is called the “Dead Zone” or “Blind Spot”, and can be quite long in less expensive TDRs.
 
Pulse technology can only measure the time between reflections and cannot interpret information between reflections such as gradual cable losses. The width of the pulse needs to be set by the operator, using a shorter pulse reduces the Dead Zone but limits the range.
 
The longer pulse widths have good range but a correspondingly larger Dead Zone. The pulse, when compared to a step TDR, has less signal energy which results in a plot that has a lower signal to noise ratio and a less clear picture of the cable.
 
Step Technology is more like a Doppler radar, where the transmitter always emits energy while the receiver simultaneously listens for returned signals. This eliminates the “Dead Zone” pitfall of pulse technology, and allows the receiver to “see” right from the TDR’s connector.
 
Since the receiver looks at a constant signal, it accurately detects information that the pulse types cannot such as the cable’s impedance along it’s length. Due to the higher energy in a step signal TDR, the signal to noise ratio is improved.
 
Couple this with the addition of noise filters and you can effectively reduce or eliminate outside interfering noise with less degradation of the received signal.

 
 
TDR Type
N Style
Telco
BNC Style
F Style
F or B Network Style
Model No.
6020-500x
6020-501x
6020-502x
6020-503x
6020-504x/505x
Accessories
Soft Carrying Case
with strand hook
and shoulder strap
P.N. 5001-1002
Included
Included
Included
Included
Included
Universal Power
Adapter
P/N 5001-0202
Included
Included
Included
Included
Included
Operations Manual
P/N 6020-3000
On CD &
Printed
On CD &
Printed
On CD &
Printed
On CD &
Printed
On CD &
Printed
Quick Start Guide:
Standard P/N 6020-
3010 or CATV P/N
6020-3011
On CD &
Printed
On CD &
Printed
On CD &
Printed
CATV ver.
On CD &
Printed
F-CATV or BNC -
standard On
CD & Printed
TDR PC Vision
Software
On CD
On CD
On CD
On CD
On CD
Test Leads Telco
P/N 6020-0250
N/A
Included
N/A
N/A
Included
Test Leads, “BNC”-
to-Alligator clips
P/N 0070-1221 or
“F”-to-Alligator
Clips P/N 0070-1220
N/A
N/A
BNC
Included
F Included
BNC or F
Included
8 AA Alkaline Batteries Nonrechargeable
units only
Optional
Installed
Optional
Installed
F –Installed
BNC-Optional
Internal Rechargeable Models
6020-R500x
6020-R501x
6020-R502x
6020-R503x
6020-R504x/5x
8 AA NiMH
2000mAhr
P/N 0010-0218
Installed
Installed
Installed
Installed
Installed
DC Vehicle Charger
P/N 6025-0250
Installed
Installed
Installed
Installed
Installed

All rechargeable TDR’s come with 8 AA NiMH cells installed. Some non-rechargeable models come with 8 AA alkaline cells installed. Replacement NiMH cells are available from AEA Technology (P/N 0010-0218) or can be replaced with any reliable commercial brand sold in local stores. Additionally, rechargeable units can operate on AA alkaline cells and non-rechargeable units can operate on externally recharged AA NiMH or NiCd cells.

CAUTION: You should never mix cells. All 8 cells should be replaced at the same time and with the same type of cell.
 
TDR 20/20
TDR 20/20
 
 


00227
Domestic handling time
Sales tax
Will usually ship within 1 business day of receiving cleared payment.
Seller charges sales tax for items shipped to: CA (8.75%).
Return policy
Item must be returned within
Refund will be given as
Return policy details
7 days after the buyer receives it
Money Back
For warranty on new products please ship product directly to the manufacturer. You would have to request an RMA number from the factory or we can help you get your RMA number. Any questions please call us Toll Free in the USA at 1-866-744-3014.  Shipping is not refundable.
The buyer is responsible for return shipping costs.

Payment details
Payment methodPreferred/AcceptedBuyer protection on eBay
Credit or debit card through PayPal
PayPal Preferred
Pay with and your full purchase price is covered | See terms
Seller's payment instructions
Any questions please call us Toll Free in the USA at 1-866-744-3014 or email us at sales@SignalTestInc.com
Seller assumes all responsibility for this listing.

About eBay | Announcements | Security Center | Resolution Center | eBay Toolbar | Policies | Government Relations | Site Map | Help
Copyright © 1995-2009 eBay Inc. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Use of this Web site constitutes acceptance of the eBay User Agreement and Privacy Policy.
eBay official time